A padel court is not lit to a wattage, it is lit to a class. Get the class wrong and the court is either rejected at homologation or complained about by the neighbours. This page sets out what EN 12193 requires, how the three classes translate into lux, uniformity and glare, what light-trespass rules an outdoor court must satisfy, what the electrical inspector checks, and the documents a lighting package has to include before a permit file is complete.

200 / 300 / 500 luxEN 12193 Classes III, II and I
0.5 to 0.7Minimum Uniformity Emin / Emed by Class
GR 50 or lowerGlare Rating Quoted in Specifications
2 to 25 luxLight-Trespass Limit at a Window (Zones E1 to E4)
Quick Answer: A padel court is specified to a lighting class, not to a wattage. Class III is 200 lux outdoors and 300 lux indoors for recreational and school play, Class II is 300 lux for club and league play, and Class I is 500 lux outdoors or 750 lux indoors for competition. The class fixes the lux level, the uniformity between the brightest and the darkest point of the court, and the glare rating. EN 12193 is the reference standard quoted across Europe, and in Spain an outdoor installation also has to satisfy the light-trespass limits of the E1 to E4 zones (2, 5, 10 and 25 lux at a neighbouring window) and the electrical requirements of the outdoor lighting installation rules. All of it is proven with one document: the photometric study.

1. Which standard actually applies to your padel court

2. The three EN 12193 classes and the lux levels behind them

3. Uniformity, glare and what a lux average hides

4. What each class means in fixtures, poles and load

5. Light trespass: the number that decides your permit

6. The electrical side: what an inspector checks

7. Sizing check: from lux to lumens

8. The document pack your supplier should hand over

9. Red flags in a lighting quotation

10. Lighting standards FAQ

Which standard actually applies to your padel court?

Almost every professional specification in Europe points to the same document. What changes from market to market are the national rules layered on top of it, and those are the ones a permit officer reads.

The reference document is EN 12193, “Light and lighting — Sports lighting”, adopted nationally without technical change, so you will also meet it as BS, DIN, NF, UNI, NP or PN EN 12193. It is not a product standard: it does not tell you which luminaire to buy, it tells you which class a court belongs to and what that class has to deliver in lux, uniformity and glare.

Two layers sit on top of it: the national or regional rule governing what your installation sends into the sky and into the windows next door, which is where a project is most often refused; and the electrical installation rule, which decides whether the circuit, the earthing and the protection are acceptable.

MarketDocument your specification should quoteWhat it fixes
Europe, generalEN 12193Class, lux level, uniformity, glare, colour
SpainEN 12193 plus the sports-facility guidance of the Consejo Superior de Deportes, and RD 1890/2008 with the outdoor lighting installation rules (ITC-BT-09) of the electrical code300 lux outdoor and 500 lux indoor as a national baseline at 70% uniformity; light trespass and upward light limits; circuit, earthing and protection
United KingdomBS EN 12193 plus obtrusive-light guidance from the lighting professionClass levels and the spill limits a planning condition usually copies
GermanyDIN EN 12193 plus state sports-facility guidanceClass levels, uniformity and the immission values used in residential complaints
France / Italy / Poland / PortugalThe national adoption of EN 12193, plus light-pollution rules (in France a national decree, in Italy mainly regional law)Class levels, and the curfew, upward-light and spill limits applied locally
United States and GCCIES recommendations and the local light-trespass ordinance; in the Gulf, the municipality permit plus the project specificationLevels are quoted in foot-candles in the US (1 fc = 10.76 lux) and the ordinance, not the standard, sets the spill limit

Practical note. The document that stops a project is rarely the standard. It is the municipal ordinance, which may be stricter than the national rule and is written by someone who has already dealt with complaints about a nearby court. Ask for it before the lighting is designed, not after.

The three EN 12193 classes and the lux levels behind them

One decision — what the court is sold for — fixes the lights, the poles, the load and the electricity bill for the next decade. The table below is the whole conversation.

Illuminance is measured horizontally, at court level, in lux. The class sets the average and the uniformity, and the average on its own is meaningless without the uniformity figure next to it.

ClassWhat the court is used forOutdoor illuminanceIndoor illuminanceUniformity (minimum)
Class IIIRecreational play, schools, basic training, private courts200 lux300 lux0.5 to 0.6
Class IIClub play, leagues and regional competition, commercial coaching300 lux500 lux0.7
Class INational and international competition, televised or streamed play500 lux750 lux0.7

Two qualifications matter in a purchase order. Published reproductions of the standard's tables differ in the last decimal: some quote a uniformity of 0.5 for the recreational class and 0.6 for club play, others 0.6 and 0.7, because the value depends on whether the court is indoor or outdoor and on how the national body reads the table — the Spanish sports-facility guidance, for example, works with 300 lux and 500 lux at 70% uniformity, which is stricter than the European minimum. Ask for the uniformity figure explicitly and write the agreed number into the specification; a design that meets the average and misses the uniformity is the most common failure in submitted files. And indoor courts are lit a step above the outdoor equivalent, because the roof and walls remove the daylight that softens an outdoor court.

The class is also a commercial decision. A court sold at 200 lux cannot host a federation event, so the honest question is not “what is the best lighting” but “what will this court be booked for in three years”. The gap between Class III and Class II is roughly one extra pair of fixtures — far cheaper now than a retrofit later.

Padel court lighting poles and LED projectors specified to meet EN 12193 class levels, uniformity and glare limits

Uniformity, glare and what a lux average hides

Two installations can both claim 300 lux, and only one of them can pass. The difference is the corners, and the number that proves it is in the photometric study.

Four figures travel together in a compliant design, and a quotation that gives you one of them has given you none:

Average illuminance (Emed) is the 200, 300 or 500 lux of the class, measured on a grid over the playing surface rather than read from a single meter position in the middle of the court. Uniformity (Emin / Emed, and Emin / Emax in some national tables) is the ratio between the darkest point and the average: a 300 lux average with 120 lux in a corner is not a 300 lux court, because the ball disappears against a dark background on exactly the smash that decides the game.

Glare is normally capped by a glare rating of GR 50 for the club and competition classes outdoors and GR 40 or lower indoors, with a UGR limit quoted instead in some specifications; in padel this is not only comfort, since the ball is followed against the glass and the mesh. Colour sits in the 4000 to 6500 K range with a colour rendering index of 60 or higher for club play, rising to 70 or 80 where the court is televised, and flicker-free drivers become a requirement as soon as the court is filmed or streamed.

All four are properties of the whole installation rather than of the luminaire, which is why pole layout decides them. Mounting heights of roughly 6 to 8 m, asymmetric sport optics and a controlled tilt — typically no more than 20 to 30 degrees — push light onto the court and keep it off the neighbouring plot. Two powerful units aimed down the middle of the court will hit the lux figure in a sales document and fail the uniformity figure in the calculation grid.

What each class means in fixtures, poles and load

The count below is the mainstream LED configuration for a single 20 × 10 m court. Treat it as a sanity check against any quotation, not as a design.

ConfigurationTypical fixture count and wattageElectrical loadFits
LED, recreational4 to 6 fixtures at 150 to 180 W, 6 m poles0.6 to 1.0 kWClass III
LED, club play6 to 8 fixtures at 200 to 250 W, 6 to 8 m poles1.2 to 1.8 kWClass II, and the mainstream commercial specification
LED, competition8 to 12 dimmable fixtures at 250 to 300 W, higher masts or hall structure2.0 to 3.2 kWClass I, including streamed play
Metal halide, existing8 lamps at 400 W with ballasts3.2 to 5.5 kWCompares at roughly three times the energy of the LED equivalent, and loses output as it ages

Modern LED luminaires run at roughly 140 to 170 lumens per watt, which is what makes the load figures above possible at these lux levels; metal halide installations that were compliant when they were built often are not compliant now, because lamp output falls well before the court is relamped. Keeping the poles and changing only the luminaires is usually the cheapest route to a compliant class, but it is still a fresh photometric calculation, because the optics have changed. The full range of padel court lighting systems, poles and controls we build follows the same class logic.

Light trespass: the number that decides your permit

The limit is not on your court. It is on your neighbour's window, and it is the reason outdoor padel projects are refused or forced to dim after 22:00.

Light trespass is the light from your installation that lands where it was not intended: on a facade, through a bedroom window, or into the sky. Spain regulates it explicitly in RD 1890/2008, which divides the territory into four zones and caps the vertical illuminance measured at the window. The values below are those an outdoor court is normally designed against, taken from the light-trespass table of the regulation; they apply to the vertical plane at the height where a window can be affected.

ZoneWhere it usually appliesMaximum vertical illuminance at the windowMaximum intensity per luminaire
E1Dark areas: natural parks, observatory surroundings2 lux2,500 cd
E2Low-brightness areas: rural and peri-urban5 lux7,500 cd
E3Medium-brightness areas: residential urban zones10 lux10,000 cd
E4High-brightness areas: commercial and mixed urban centres25 lux25,000 cd

Those four numbers explain most of the design compromises on a padel project in a residential area. If the nearest housing is 15 m away and the site is classed E2, the answer is not a brighter court but a better-aimed one: backlight shields on the luminaires facing the houses, poles set on the far side of the court where the layout allows, and a dimming profile that drops the court after the last booked slot. A dimmable installation is the cheapest insurance against a complaint, and in many municipalities the curfew is a permit condition anyway.

Check your own ordinance before design starts. Municipal limits can be stricter than the national zone table, and councils that have already dealt with complaints tend to write very specific conditions: no light above a stated level at a stated address, at a stated hour.

Request a Lighting Compliance Pack

Send us the court layout, the site address or the nearest housing distance and the class you intend to sell, and we will return the photometric study with the calculation grid, the uniformity and glare figures, the light-trespass check against the zone that applies to you, the luminaire and pole schedule with its electrical load, and the document set a permit file normally asks for — together with the quotation and the lead time.

Get a Quote → Chat on WhatsApp

Prefer an instant answer? Ask the AI assistant at the bottom-right.

The electrical side: what an inspector checks

Lighting standards get the court accepted by the sport. The electrical installation rules get it accepted by the authority, and they are the part buyers most often forget to specify.

An outdoor padel court is an outdoor lighting installation, and in Spain that means the outdoor lighting instruction of the low-voltage electrical code applies to it: a dedicated circuit with its own protection, correct earthing, and surge protection where the drivers are exposed.

Ingress and impact protection. IP65 is the floor for an outdoor sports luminaire, and IK08 or better matters specifically on padel, because the poles and the luminaire bodies sit inside the playing volume and take ball strikes. A luminaire with the right lux figure and the wrong IK rating is a warranty conversation waiting to happen.

Driver access. Drivers fail first, so they should be replaceable from ground level or from a service position without a platform, and the junction boxes should sit above the drainage or flood level of the court.

Indoor and covered courts. Inside a hall or under a full canopy the rules change shape: emergency lighting becomes part of the design, heat build-up has to be allowed for in the driver specification, and the structure has to accept the luminaires without weakening the roof. Ask for the as-built circuit schedule and the installer's electrical certificate as part of the delivery, not afterwards — both are normally required in the permit file.

Indoor padel court lit to a competition class, where emergency lighting, driver access and heat management are also checked

Sizing check: from lux to lumens

One formula is enough to tell whether a lighting quotation is plausible, and it takes two minutes with a calculator.

The installed luminous flux you need is the illuminance level multiplied by the court area, divided by the utilisation factor of the optics and the maintenance factor that accounts for dirt and LED ageing:

Installed lumens = lux × court area ÷ (utilisation factor × maintenance factor)

Take a 20 × 10 m court (200 m²) sold as club play, so Class II at 300 lux, with a utilisation factor of 0.45 for a sports optic at the mounting height and a maintenance factor of 0.8:

300 × 200 ÷ (0.45 × 0.8) = about 167,000 installed lumens

Option for a 300 lux courtInstalled lumensVerdict
2 × 500 W floodlights, all aimed down the centreabout 110,000 lmFails the level and fails uniformity: bright in the middle, dark at the back corners
6 × 200 W LED at 150 lm/Wabout 180,000 lmPlausible for Class II if the optic and the pole layout support the uniformity
8 × 200 W LED at 150 lm/Wabout 240,000 lmComfortable Class II with headroom for ageing, and dimmable to a lower level off-peak
8 × 400 W metal halideOver-lit when new, under-lit at end of lifeCompliant on paper in year one, and roughly three times the energy of the LED options

Run the same formula on any quotation. If it does not clear about 167,000 maintained lumens for a 300 lux court, either the level or the uniformity is going to fail — and the only way to know which is to see the calculation grid.

The document pack your supplier should hand over

Compliance is a paper trail. If a supplier cannot produce these seven items, the class claim cannot be verified by your engineer, your client or the authority.

DocumentWhat it proves
Photometric study for your court layoutAverage illuminance, uniformity, glare and the calculation grid — the document that proves the class
Photometric files (.ies or .ldt) for the offered luminaireThat your own engineer can reproduce the study independently, and can re-run it if the layout moves
Luminaire and driver datasheetsLumens per watt, colour temperature, colour rendering, IP and IK ratings, dimming protocol, and the LM-79 or LM-80 test data behind the ageing assumption
Light-trespass calculationThe vertical illuminance at the relevant window position against the zone limit that applies to your site
Electrical load schedule and as-built circuit diagramThat the supply, protection and cable sizes match the installation, and that a future service call can diagnose it
Installer's electrical certificate, issued locallyThe piece of paper the authority actually files, and the one no supplier from abroad can sign for you
Warranty terms and spare-part listCover for the luminaires and separately for the drivers, plus the replacement part references while the product is still in production

For a court being prepared for federation tournaments, the class is documented in the homologation file alongside the dimensions, the surface and the enclosures — and lighting is the item most often left to last.

Red flags in a lighting quotation

Every item below is a claim that cannot be verified, so it cannot be defended if the court is inspected.

  • A lux figure with no photometric study behind it, or a single “average lux” presented as if it settled the question. Ask for the calculation grid; a real design produces one in an afternoon.
  • No uniformity and no glare figure, and no mention of which optic is aimed where.
  • A high lux promise from two or three floodlights. It is arithmetically possible and geometrically wrong.
  • Watts offered as a substitute for lumens, optics and class. The customer is buying illuminance on a court, not kilowatts on a pole.
  • The maintenance factor and ageing ignored, so the court is compliant in the study and non-compliant after three years of use.
  • No mention of IP or IK rating on a court where the fixtures live inside the playing volume.
  • Light trespass not addressed, and no dimming or curfew option offered when housing is close — the difference between a compliant installation and a complaint.

Padel court lighting standards FAQ

The six questions that decide most lighting specifications, with the short answers.

It depends on the class. Class III, for recreational and school play, is 200 lux outdoors and 300 lux indoors; Class II, for club play, leagues and training, is 300 lux outdoors and 500 lux indoors; Class I, for competition and streamed play, is 500 lux outdoors and 750 lux indoors. National guidance may sit above the standard, and the lux figure only means something next to its uniformity figure, so read the two together.

The standard itself is not a law; it is the reference that specifications, insurers and tournament regulations point to. What is legally binding is the national and municipal layer: in Spain the light-trespass and upward-light limits of RD 1890/2008 and the electrical requirements for outdoor lighting, plus whatever your municipal ordinance adds. In practice you comply with both at once: the photometric study proves the standard, and the trespass calculation plus the electrical certificate satisfy the authority.

As a mainstream reference for a 20 × 10 m court: four to six LED fixtures of 150 to 180 W on roughly 6 m poles for recreational play, and six to eight fixtures of 200 to 250 W on 6 to 8 m poles for club play, about 1.2 to 1.8 kW; competition lighting takes eight to twelve dimmable fixtures on higher masts. The count is not the specification, though: pole positions, mounting height and the optic produce the uniformity, so two offers with the same fixture count can give very different courts.

Light trespass is light from your installation that reaches a place it was not meant to reach, most critically a neighbouring window. Where the Spanish regulation applies, the site falls into a zone from E1 to E4 and the vertical illuminance at an affected window is capped at 2, 5, 10 or 25 lux respectively, with a matching limit on the intensity of each luminaire. Complying is a design rather than a brightness decision: backlight shielding, asymmetric optics, poles away from the boundary and a dimming or curfew profile.

In most markets, yes, together with the electrical documentation and often the trespass calculation specifically. Ask for the study with the calculation grid, the average and minimum illuminance, the uniformity ratio, the glare rating and the photometric file for the luminaire, so a different engineer can re-run it. The as-built circuit diagram and the electrical certificate come from your side, not the supplier's.

Usually yes, and it is normally the cheapest route to a compliant court, provided the pole height and spacing suit the class you are targeting and the new luminaires respect the tilt limits that keep light off neighbouring property. Three things still have to be checked: the wind load and head weight on the existing masts, the cable and protection capacity for the new load, and a fresh photometric study, because the optics have changed even though the poles have not. An LED retrofit typically cuts the lighting load to about a third of an equivalent metal halide installation.

Get Your Court Designed to the Right Lighting Class

Tell us the court dimensions, the country or region, the nearest housing distance, and whether the court is open, covered or indoor. We will send the class recommendation with its lux and uniformity targets, the pole and luminaire schedule with the electrical load, the light-trespass check where the local rules apply, and the compliance documents your permit file will ask for — together with the quotation and the lead time.

Get a Quote → Chat on WhatsApp